The main exception to this rule is the TCE system whose configuration is stored only within the database. Therefore any changes, including the thickness setpoints, should be checked when a backup database is activated. If a backup database is activated while the line is running, it is important to switch off the thickness scanning gauge to prevent the TCE from controlling to old setpoints. The gauge can be restarted after the setpoints are checked and corrected if necessary.