Ladies and gentlemen on the Siemens Support, the question refers to the configuration of a S7-1515 (or S7-1515F) what unfortunately was not available in the Produktauswahlmenu.
Problem: parts of a TSEND_C or TRCV_C-configuration are not permanent.
Background: In the Network Configuration A S7-1515 are ISO-on-TCP-connections configured,What about an installed CP1543-1 are to communicate. These connections are to be transferred by TSEND_C or TRCV_C data. To configure the send/receive order I open the TSEND_C or TRCV_C-settings dialog and select the appropriate "connection data" from the drop-down menu. Only then will be the first time a part of the settings to take effect.For example, there are still first is not the correct interface (CP1543-1) is selected. Until now, when I select the "Connection Information" again, all the data will be taken from the connection settings (including Interface, IP-address, etc. ) .
is the project now closed and opened again,The TSEND_C / TRCV_C configuration when opening the Settings will revert to the State, which, as described above, when only one-time select the "Connection data sets. i.e. interface, address, etc. are no longer correct preselected.
The behavior can be adjusted for various projects. For the project planning is TIA V13 SP1 Update 3.Each CPU and CP have the latest firmwares.
how to avoid this problem ?
series system: screenprints to explain
Sincerely,
Andreas Dillhofer
DispatchInfos:
"How does your automation product? ": "technical questions about the function and integration. "
"how urgent is your request? ": "Normal"