In order to parameterize the device externally, the parameterization code is required in the form of a Data Matrix containing the desired reader parameters. Data Matrix code cards detailing the step-by-step process for externally parameterizing the device are printed in the operating instructions for
the reader.
The reader can be parameterized only within ten minutes of being switched on. If a key is pressed after ten minutes of the device being switched on, a
visual signal is given by the LEDs (LED1, yellow/LED2, red/LED3, yellow/LED4, yellow/LED5, yellow, flashing for two seconds).
• The switchover from normal mode to parameterization mode is made by pressing button 2 on the back of the reader. To switch the device over,
button 2 must be pressed and held for more than two seconds. LED3 then flashes.
Note: Parameterization mode is exited automatically if the device is inactive for one minute. In this case, the reader reverts to normal mode and
operates without the settings having been changed.
• Place the parameterization code in the field of vision of the camera module. After the parameterization code is detected, the green LED2 lights
up for one second. In the event of an invalid parameterization code, LED2 lights up red for two seconds.
• Briefly pressing button 2 will end parameterization mode.
Default values
On delivery the parameters of the read head PGV have the following default values: